AC Volt Meter
Indicates the voltage supplied to the panel. The test switch on
the panel below the meter is used to select to monitor hot line
1 or hot line 2.
AC Main Breaker
Protects the general distribution network. This breaker is very
sensitive. The resulting power surge that occurs when connect
-
ing the dock side cord may cause the main breaker to trip. To
avoid this surge, always turn the main breaker to the “OFF”
position before plugging or unplugging the shore power cord.
The AC main breaker also is equipped with a relay that will
cause the main breaker to trip when reversed polarity current
is detected.
There is a main breaker for the shore circuit and the generator.
Sliding safety covers on the main breakers prevent activating
circuits for the generator and shore line simultaneously.
Fault Light
The red light indicates reverse polarity current supplied to
the panel. This situation will cause the red light to remain
lit and the special relay attached to the main breaker will
automatically turn the main breaker off. If reverse polarity
is achieved, immediately turn off all cabin AC breakers and
dockside outlet breakers. Disconnect the power cable from
the dockside outlet and notify a qualified electrician to check
the dockside wiring.
Power Available Light
The green light indicates that correct AC current is being sup
-
plied to the panel.
240-Volts AC
Air Conditioner
Supplies 240-volt AC electrical current to the air conditioning
control panel and the air conditioner/freezer raw water pump
when this option is installed.
Heater 1
Supplies 240-volt AC electrical current to the flybridge air
conditioning control panel and heater.
Heater 2
Supplies 240-volt AC electrical current to the salon air condi-
tioning control panel and heater
Heater 3
Supplies 240-volt AC electrical current to the forward cabin air
conditioning control panel and the air conditioner and heater
Note: These breakers will trip if sea water is not be-
ing supplied to the air conditioning unit. If this
breaker trips, reset and check for water flow out
of the air conditioning thru-hull. Refer to the air
conditioner owner’s manual for additional infor-
mation.
120-Volts Buss A
Reserved
Reserved for additional AC equipment.
Outlets Port
Supplies 120-volt AC electrical current to the port ground fault
interrupter (GFI) electrical outlets.
Outlets FWD
Supplies 120-volt AC electrical current to the forward cabin
ground fault interrupter (GFI) electrical outlets.