fied by a black plastic cover that rotates to the open and closed
positions. The connector has an automatic valve that is always
closed until the washdown hose is connected.
The hose requires a special fitting that snaps into the connector
and activates the automatic valve. The cover on the connector
should always be in the closed position to keep the connector
clean when the washdown hose is not attached. Contact your
Albemarle dealer for information on replacement fittings and
hoses.
ALWAYS TURN THE RAW WATER PUMP SWITCH TO
THE “OFF” POSITION WHEN LEAVING THE BOAT
UNATTENDED.
6.3 Livewell
Sea water is provided to the livewell pump by a thru-hull fitting.
This pump is designed to carry a constant flow of water to the
livewell. There is a sea strainer on the intake side of the pump
located in the aft bilge compartment. This should be checked
frequently and cleaned as necessary. The pump is activated
by the Livewell breaker in the DC panel and a switch in the
cockpit switch panel.
An overflow tube in the drain fitting automatically controls
the water level in the livewell. Always turn the pump off at the
breaker panel when the livewell is not in use.
To fill the livewell, insert the overflow tube into the drain
fitting at the bottom of the livewell. Make sure the valve at
the intake thru-hull fitting is open and activate the Livewell
breaker. When the water level reaches the overflow, it will
begin to circulate.
To drain the livewell, turn off the livewell pump and pull out the
overflow tube in the drain fitting at the bottom of the livewell.
When the livewell has completely drained, use the washdown
hose to flush the livewell and drain of debris.
Note: Do not use the livewell as a dry storage area when
it is not in use. Sea water could accidently be
delivered to the livewell from the thru-hull fitting
and damage equipment stored there.
6.4 Air Conditioning and
Optional Freezer
The air conditioners and bait freezer are sea water cooled.
240-volt centrifugal raw water pumps supply sea water that
cools the condensing units as it circulates through the system
and is discharged overboard. The pump for the flybridge air
conditioner and freezer is located below the water line in the
engine compartment and activated whenever 240-volt current
is available and the air conditioning or freezer system is operat
-
ing. The pump for the salon and lower berth air conditioners
in located in the forward bilge compartment.
Sea water is supplied to each pump from a thru-hull fitting
located in the hull near the pump. A sea strainer between the
pump and thru-hull fitting protects the system from contami
-
nants that could damage the pump or the system. Make sure
the pumps receive adequate sea water by periodically cleaning
the sea strainer baskets. The procedure for cleaning strainer
is outlined in the maintenance section of this chapter. You
also should refer to the manufacturer owner’s manuals for
more information on the operation and maintenance of the air
conditioners and freezer .