410 Convertible
136
PROBLEM
CAUSE AND SOLUTION
TROUBLESHOOTING
GUIDE
ACCESSORY PROBLEMS
The washdown or fresh water pump fails to turn off after
all outlets are closed.
Reduction in water flow from the bilge pump.
The automatic float switch on the bilge pump raises but
does not activate the pump.
The bilge pump will not run when the manual switch is
activated.
There is a leak in a pressure line or outlet. Repair the leak.
There is an air leak in the intake line. Repair the air leak.
The pressure switch is defective. Replace the pressure
switch.
The voltage to the pump is low. Check for corroded or loose
wiring connections or low battery.
The strainer is clogged. Clean strainer.
The pump is defective. Repair or replace the pump.
Impeller screen plugged with debris. Clean screen at the
base of the pump.
The discharge hose is pinched or clogged. Check discharge
hose and clean or repair.
Discharge hose is sagging below the pump and creating an
air lock. Reroute hose so it runs uphill from the pump to
the thru-hull fitting.
Low voltage to the pump. Check the battery and wire
connections.
The circuit breaker near the battery switch has blown. Reset
the circuit breaker.
The battery is dead. Charge or replace the battery.
The pump impeller is jammed by debris. Clean pump
impeller housing.
The wire connections in the bilge have corroded. Replace
connectors and secure above the bilge waterline.
The automatic switch is defective. Replace the switch.
The pump is defective. Replace pump.
The circuit breaker supplying the switch has tripped. Replace
or reset the circuit breaker.
The battery switch is off. Turn on the battery switch and
bilge pump breaker.
The pump impeller is jammed by debris. Clean pump
impeller housing.
The wire connections in the bilge have corroded. Replace
connectors and secure above the bilge waterline.
The switch is defective. Replace the switch.
The pump is defective. Replace pump.